Technology

Polish physicists develop sensor that remembers light

Adobe Stock
Adobe Stock

Researchers in Poland have developed a light-sensitive device that can retain a temporary trace of previous stimulation, mimicking one feature of memory in neuronal connections. The approach could eventually help cameras and other sensors process information directly where it is received, reducing the need to send data to a separate processor.

A camera monitoring a street records a sequence of images. To determine the direction in which a cyclist is travelling, a computer must compare their position across several frames. In conventional systems, data from the sensor is sent to memory and a processor for analysis, consuming time and energy. Researchers are therefore exploring ways to perform some of this processing directly within the sensor, which would need to retain a trace of what it had just recorded.

The nervous system offers a model. Nerve cells communicate through connections called synapses, whose responses depend partly on their previous activity. In some cases, the second of two closely spaced signals triggers a stronger response than the first. The connection effectively retains a trace of its earlier stimulation for a limited time. Researchers are investigating ways to reproduce this behaviour in electronic devices.

A team from Wrocław University of Science and Technology and the Institute of Physics of the Polish Academy of Sciences studied a structure made of thin layers of zinc oxide, including a cadmium-containing variant, deposited on a silicon substrate. The material was also doped with europium, an element that changes its electrical properties.

Comparisons between samples showed that, at low europium concentrations, the structure could function as an artificial synapse stimulated by light. The findings were published in Advanced Functional Materials (doi:10.1002/adfm.78523).

The effect relies on electrical charges becoming trapped inside the material. When silicon absorbs light, the energy allows electrical charges to move, generating a current that can be measured. Some charges, however, remain trapped in particular locations within the material even after the light is switched off.

If another flash arrives before those charges are released, the sensor is still in an altered electrical state. The trapped charges affect the flow of current, producing a stronger response to the next flash. The material thus retains a temporary trace of earlier stimulation in its electrical state.

To test the mechanism, the researchers exposed the samples to a series of short light flashes and measured the resulting current. Successive pulses produced an increasingly strong response. The effect was observed with flashes lasting just one ten-thousandth of a second, separated by intervals five times longer. In one measurement, the response to the second flash was 47% stronger than the response to the first.

Despite the rapid stimulation, the individual signals remained distinguishable.

The behaviour between flashes was also significant. After the light was switched off, the current nearly returned to its baseline level, but the sensor retained a trace of the previous stimulation. This became apparent only when another light pulse arrived.

As the interval between flashes increased, the effect weakened because the trapped charges gradually escaped. The temporary memory therefore faded naturally, allowing the system to return to its initial state.

The device generated its signal using energy supplied by light, without an external power supply for that process. However, this alone does not establish that the overall system would be more energy-efficient: a complete assessment would also need to account for the power used by the light source, the readout mechanism and the rest of the electronic circuitry.

Sensors that retain a trace of recent signals could eventually help robots and other devices track changes in their surroundings. Processing some information directly where light is detected could reduce the amount of data that needs to be transferred for further analysis.

For now, the study demonstrates the operation of a single component, not a complete camera. Integrating the technology into an imaging system would require combining many such sensors and testing whether their temporary memory improves the analysis of real-world images. (PAP)

PAP - Science in Poland

kmp/ zan/

tr. RL

 

The PAP Foundation allows free reprinting of articles from the Nauka w Polsce portal provided that we are notified once a month by e-mail about the fact of using the portal and that the source of the article is indicated. On the websites and Internet portals, please provide the following address: Source: www.scienceinpoland.pl, while in journals – the annotation: Source: Nauka w Polsce - www.scienceinpoland.pl. In case of social networking websites, please provide only the title and the lead of our agency dispatch with the link directing to the article text on our web page, as it is on our Facebook profile.

More on this topic

  • The Mikroglob-2, Mikroglob-3, and Mikroglob-4 satellites, developed by Creotech Instruments (illustrative image). Photo from press release.

    Polish firm to lead €13.9m ESA space weather mission

  • Adobe Stock

    Polish researchers develop tool to measure digital hygiene

Before adding a comment, please read the Terms and Conditions of the Science in Poland forum.